Elgard General Information

The range includes anodes for the protection of steel reinforced concrete structures including
-
Mesh and Ribbon Mesh Anodes for concrete structures (NACE standard test TM0294-2001 exceeds 75 years of operation at 110mA/m2)
-
Tubular Mesh discrete anodes for protection of piers, wharfs and other difficult to protect steel reinforced concrete structures.
|
Product |
Diamond Dimensions |
Current rating @ 110mA/m2 (10mA/ft2) |
Coil Width |
Coil Length |
|
85 Ribbon Mesh |
2.5 x 4.6 x 0.6mm (0.10"x0.18"x0.025") |
2.8mA/m (0.85mA/ft) |
10mm (0.4") |
76m
(250 ft) |
|
100 Ribbon Mesh |
2.5 x 4.6 x 0.6mm (0.10"x0.18"x0.025") |
3.5mA/m (1.05mA/ft) |
13mm (0.5") |
76m
|
|
150 Ribbon Mesh |
2.5 x 4.6 x 0.6mm (0.10"x0.18"x0.025") |
5.28mA/m (1.61mA/ft) |
19mm (0.75") |
76m
|
|
170 Ribbon Mesh |
2.5 x 4.6 x 0.6mm (0.10"x0.18"x0.025") |
5.3mA/m (1.62mA/ft) |
20mm (0.8") |
76m
|
|
200 Ribbon Mesh |
2.5 x 4.6 x 0.6mm (0.10"x0.18"x0.025") |
7.0mA/m (2.13mA/ft) |
25mm (0.8") |
76m
|
|
150 Anode Mesh |
34 x 76 x 0.64mm (1.33"x3.0"x0.025") |
18.8mA/m2 (1.71mA/ft2) |
1.22m (4ft) |
76m |
|
(250 ft) | ||||
|
210 Anode Mesh |
34 x 76 x 0.89mm (1.33"x3.0"x0.035") |
24.4mA/m2 (2.22mA/ft2) |
1.22m (4ft) |
76m |
|
(250 ft) | ||||
|
300 Anode Mesh |
25 x 51 x 0.89mm (0.923"x2.0"x0.035") |
37.8mA/m2 (3.44mA/ft2) |
1.22m (4ft) |
76m |
|
(250 ft) |
For further information please contact cpc@cathodic.co.uk